MODEL
HVCA8
Ventable, pilot operated, balanced piston relief main stage with integral T-8A
control cavity - before check
SERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-21A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
The relief-before-check cartridge is a CavitySaver™ (multi-function) valve incorporating a normally closed,
balanced piston modulating element tee'd in before a check function. The valve incorporates an integral pilot control
cavity. The pilot control cavity will accept any T-8A pressure control cartridge. When the pressure at the inlet (port 2)
reaches the pilot control valve setting, the modulating element starts to open to tank (port 3), throttling flow to
regulate the pressure. The T-8A pilot section is drained to port 4. The check valve flow is from the inlet (port 2) to
the system port (port1).
TECHNICAL DATA
Cavity T-21A
Series 1
Capacity 40 L/min.
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Response Time - Typical 10 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 30 cc/min.@70 bar
Check Cracking Pressure 1,7 bar
Pilot Control Cavity T-8A
Pilot Control Valve Installation Torque 27 - 33 Nm
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990021007
Seal kit - Cartridge EPDM: 990021014
Seal kit - Cartridge Polyurethane: 990021002
Seal kit - Cartridge Viton: 990021006
Model Weight 0.14 kg.
snhy.com/
HVCA8
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
NOTES