c
2017 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
HVCA8
Ventable, pilot operated, balanced piston relief main stage with integral T-8A
control cavity - before check
SERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-21A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
The relief-before-check cartridge is a CavitySaver™ (multi-function) valve incorporating a normally closed,
balanced piston modulating element tee'd in before a check function. The valve incorporates an integral pilot control
cavity. The pilot control cavity will accept any T-8A pressure control cartridge. When the pressure at the inlet (port 2)
reaches the pilot control valve setting, the modulating element starts to open to tank (port 3), throttling flow to
regulate the pressure. The T-8A pilot section is drained to port 4. The check valve flow is from the inlet (port 2) to
the system port (port1).
TECHNICAL DATA
Cavity T-21A
Series 1
Capacity 40 L/min.
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Response Time - Typical 10 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 30 cc/min.@70 bar
Check Cracking Pressure 1,7 bar
Pilot Control Cavity T-8A
Pilot Control Valve Installation Torque 27 - 33 Nm
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990021007
Seal kit - Cartridge EPDM: 990021014
Seal kit - Cartridge Polyurethane: 990021002
Seal kit - Cartridge Viton: 990021006
Model Weight 0.14 kg.
snhy.com/
HVCA8
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
NOTES
c
2017 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
(D)BIAS PRESSURE
D 75 psi (5 bar)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
TECHNICAL FEATURES
Note! This valve deviates from Sun's normal flow path for relief valves. It is probably not useable in current Sun relief manifolds.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
the seals.
The main stage orifice is protected against contamination.
The check portion of the valve has a maximum leakage rate of less than 1 drop/minute (0,07 cc/min).
One purpose of this dual function cartridge is to offer pump isolation and relief protection in single and/or multiple pump circuits. Another purpose is to act as a main
stage in an accumulator sense, pump unload circuit.
NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into
the main stage valve to its required torque value.
The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are
sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
HVCA Ventable, pilot operated, balanced piston relief valve - before check
Model Code Example: HVCA8DNCONFIGURATION OPTIONS